Infrared Multifunction Thermometer [SKU: IMThe]
Out of stock
Features
- To measure Forehead temperature,Ear temperature and Object temperature
- 10 memory
- Backlight-Optional
- Result Indicator
- Fever alarm
- Low battery indicator
- Auto shut-off
- Fast result in 1 seconds
- Dual Scale, switchable
Contents
- 1 Thermometer
- 1 Owner’s manual
- 1 Storage case
- 2 AAA batteries
Illustration
Specification
Model | MS-T01 |
---|---|
Type | Multi Functional Thermometer |
Certification available | CE0197;FDA510(K); ISO13485;ROHS;REACH |
Measuring range | Ear/Forehead mode: 34.0℃~43.0℃(93.2℉~109.4℉) Object mode: 0℃~100℃(32℉~212℉) |
Measuring site | Ear canal(Ear Mode),Forehead(Forehead Mode) |
Laboratory accuracy | Ear/Forehead mode: ±0.2℃ (0.4℉) during 35.5℃~42.0℃ (95.9℉~107.6℉) at 15℃~35℃ (59.0℉~95.0℉) operating temperature range ±0.3℃ (0.5℉) for other measuring and operating temperature range Object mode: ±4% or ±2℃(4℉) whichever is greater |
Display resolution | 0.1℃ or 0.1℉ |
Measure time | Ear mode/Object mode: Approx. one second Forehead: Approx.three seconds |
Operating temperature range: | Forehead/Object mode:10℃~40℃(50℉~104℉), 15%~85%RH, non-condensing Atmospheric Pressure:700hPa ~ 1060hPa |
Storage and transport temperature range | -25℃~ 55℃ (-13℉~131℉), 15%~95%RH, non-condensing Atmospheric Pressure:800hPa ~ 1060hPa |
Clinical accuracy | Clinical bias: 0.05℃(0.09℉) Clinical repeatability:0.11℃(0.20℉) Limits of agreement:1.04℃(1.88℉) |
Dimension | 155*39*50mm |
Weight | Approx.85grams(with batteries) |
Battery | DC3V(2×AAA battery) |
Battery life | Approx. 1 year/6000 readings |
Ingress protecting rating | IP22 |
Instructions
Forehead Use
Install the forehead cap. Press the Power Button to switch on the thermometer and the display is activated to show all segments. |
|
After self-checking appears on the display screen with beeps, so you can start a new measurement. Place the probe with the forehead cap fitted on the temple. |
|
Press the START button to start measurement.Move the thermometer smoothly over the forehead to the other temple and back. The measured value appears on the display and the end of the measuring is signalled by a short beep. |
|
To prolong battery life, press the Power Button to turn unit off after testing is complete. If no action is taken, the unit will automatically shut off after around 1 minutes.
Store the thermometer in its protective case. |
Ear Use
Remove the forehead cap. Press the Power Button to switch on the thermometer and the display is activated to show all segments. |
|
After self-checking appears on the display screen with beeps, so you can start a new measurement. Make sure that the sensor tip and the ear canal are clean. As the ear canal is slightly curved, you have to pull the ear slightly up and backwards before inserting the sensor tip. |
|
Press the START button to start measurement.Move the thermometer smoothly over the forehead to the other temple and back. The measured value appears on the display and the end of the measuring is signalled by a short beep.
Note: A waiting period of 20 seconds between testing is recommended to avoid excessive cooling of the skin. |
|
To prolong battery life, press the Power Button to turn unit off after testing is complete. If no action is taken, the unit will automatically shut off after around 1 minutes.
Store the thermometer in its protective case. |